Model
|
Cavity
|
Operating Pressure
( bar )
|
Flow
( l/min )
|
Hysteresis
|
HSP08-47C
|
SAE-08-4
|
240
|
11.4
*1
|
less
than 7%
|
HSP10-47C
|
SAE-10-4
|
248
|
22.7
|
Model
|
Coil Duty Rating
|
Internal Leakage
|
Installation Torque
( Nm )
|
Weight
( kg )
|
HSP08-47C
|
continuous
up to 115% of nominal voltage
|
164
cc/min. max.
per
side at 207 bar
|
24.4
~ 27.1
|
0.74
|
HSP10-47C
|
164
cc/min. max.
per
side at 248 bar
|
32.5
~ 35.3
|
1.45
|
*1 Flow rate is based on 50% duty cycle and
coil temperature of 20°C (140°F). Consult factory if higher duty cycle
and coil temperatures are anticipated.
* Operating temperature : -35 ~ 100°C (
-31 ~ 212°F )
|